- Take out or cut slots into horizontal mortar joint to specified depth and at required vertical spacings
- Vacuum out the slots and thoroughly flush with water
- Insert a 10mm (approx) depth bead of Bond Flex cementitious grout into back of the slot
- Push Bar Flex reinforcement into the bead of grout to obtain good even coverage
- Insert a second 10mm (approx) depth bead of Bond Flex cementitious grout up against existing grout
- Push a second piece of Bar Flex reinforcement into the bead of grout to obtain good even coverage
- Insert a bead of Bond Flex cementitious grout over the exposed rod and iron into the slot using the finger trowel
- Point up or fill the joint and leave ready for any decoration
Guidelines
- Depth of slot to be 40 to 55mm
- Bar Flex to extend a minimum of 500mm each side of the opening
- Where the Bar Flex have to be joined in long runs a minimum of 500mm overlap should be allowed