BF·08 Beaming (Solid Wall)

Method Statement
- Rake out or cut slots into horizontal mortar joint to specified depth and at required vertical spacings
- Vacuum out the slots and thoroughly flush with water
- Insert a 10mm (approx) depth bead of Bond Flex cementitious grout into the back of the slot
- Push the first piece of Bar Flex reinforcing into the bead of grout to obtain good even coverage
- Insert a second 10mm (approx) depth bead of Bond Flex cementitious grout up against first piece of Bar Flex and existing grout
- Push second piece of Bar Flex reinforcing into the bead of grout to obtain good even coverage
- Insert a further bead of Bond Flex cementitious grout over the exposed Bar Flex and iron into the slot using the finger trowel
- Point up or fill the joint and leave ready for any decoration
Guidelines
- Depth of slot to be 55 to 70mm
- Where the Bar Flex have to be joined in long runs a minimum of 500mm overlap should be allowed
- Top and bottom reinforcements should be positioned as far apart as practicable, up to a maximum distance equivalent to 12 brick courses (approx 900mm)